Customer Service: 010 541 0652

7798 - CO2 Temperature RH Indoor Air Quality Monitor

R3,246.68

The monitor is equipped with a large LCD display which displays the CO2 value (with a good, normal and poor air quality indicator), year-month-date, hour-minute, air temperature as well as relative hu..

This product has a minimum quantity of 10

Tags: CO2, temperature, relative humidity, indoor, air quality, monitor, AZ Instrument Corp

7798 - CO2 Temperature RH Indoor Air Quality Monitor

The monitor is equipped with a large LCD display which displays the CO2 value (with a good, normal and poor air quality indicator), year-month-date, hour-minute, air temperature as well as relative humidity. The monitor is tilted at an angle of 15 degrees to provide an easy to read angle and also displays the real-time date and time. The monitor uses NDIR (non-dispersive infrared) waveguide technology, as well as CO2 automatic background calibration for long term drift compensation.

 

Highlighted Features

  • A large LCD display is equipped on this monitor which displays the CO2 value with a good, normal and poor air quality indicator, year-month-date, hour-minute, air temperature as well as relative humidity.
  • The monitor is tilted at an angle of 15 degrees to provide an easy to read angle and also displays the real-time date and time.
  • NDIR (non-dispersive infrared) waveguide technology, as well as CO2 automatic background calibration for long term drift compensation, is used on this monitor.

 

In what environment does this instrument operate?

The 7798 AZ CO2 Temperature RH Recorder can be used as the CO2 monitor for the air quality index in all workspaces, offices, hospitals, schools, stations, or homes and can be applied in public areas such as factories, residential spaces, commercial buildings, and hotels. It is also suggested in regulations of industrial hygiene in some countries.

 

What measurements does this instrument support?

The 7798 AZ CO2 Temperature RH Recorder supports the following measurements: indoor air quality (IAQ) index, CO2 level, air temperature, and humidity.

 

For more information visit AZ Instrument Corp.

Testing Instruments
Instrument Air Temperature Accuracy ±0.6°C, ±0.9°F
Instrument Air Temperature Range -10~60°C, 14~140°F
Instrument Air Temperature Resolution 0.1°C, 0.1°F
Instrument Air Temperature Response Time < 2 mins (90% step change)
Instrument CO2 Measurement Accuracy ±50 ppm ±5% of reading (0~2000 ppm), other ranges are not specified
Instrument CO2 Measurement Range 0~9999 ppm (2001~9999 ppm out of scale range)
Instrument CO2 Measurement Resolution 1 ppm
Instrument CO2 Response Time < 2 mins (90% step change)
Instrument CO2 Warm-up Time 30 seconds
Instrument Humidity Accuracy ±3% RH (at 25°C, 10~90% RH); others ±5% RH
Instrument Humidity Range 0.1~99.9% RH
Instrument Humidity Resolution 0.1% RH
Instrument Humidity Response Time < 10 mins (90% step change)
Instrument Meter/LCD Size Meter: 120 (Diameter) * 80 (Depth) mm LCD: 60(H) * 82(W) mm
Instrument Operating RH% 5~80% RH (avoid condensation)
Instrument Operating Temperature 0~50°C
Instrument Sampling Point 15999 points (5333 points for each parameter)
Instrument Sampling Rate 1sec to 4 hr 59 mins 59 sec
Instrument Storage RH% 50~90% RH (avoid condensation)
Instrument Storage Temperature -20~50°C
Instrument Weight ~200g