USB Weather Station
This rugged weather station is Onset’s most durable outdoor environmental monitoring solution. Users can easily configure the HOBO U30-NRC Weather Station to fit their application needs. Use up to 15 ..
- Brands ONSET
- Product Code: U30-NRC
- Availability: 7-10 Days
Available Options
Tags: weather, station, logger, system, outdoor, indoor, temperature, humidity, soil moisture, windspeed, rainfall, u30-nrc
USB Weather Station
This rugged weather station is Onset’s most durable outdoor environmental monitoring solution. Users can easily configure the HOBO U30-NRC Weather Station to fit their application needs. Use up to 15 channels to collect environmental data and then upload to HOBOware® software for analysis. HOBOware Pro is recommended for extended features, see the comparison here. The U30-NRC has four configurable systems, that can be configured below, that consist of the following part numbers: U30-NRC-000-05-S100-000, U30-NRC-000-10-S100-000, U30-NRC-VIA-05-S100-000, and U30-NRC-VIA-10-S100-000.
Highlighted Features
- All electronics are housed within a rugged double-weatherproof, tamper-proof enclosure
- Setup is quick and easy with plug-and-play sensors
- Fast data offload via USB
- Optional analog inputs with sensor excitation
- Includes relay that can be activated on user-defined alarm conditions
In what environment does this data logger operate?
This data logger operates in indoor and outdoor environments.
What measurements does this data logger support?
The U30-NRC data logger supports the following measurements: 4-20mA, AC Current, AC Voltage, Air Velocity, Amp Hour (Ah), Amps (A), Barometric Pressure, Carbon Dioxide, Compressed Air Flow, DC Current, DC Voltage, Differential Pressure, Gauge Pressure, Kilowatt Hours (kWh), Kilowatts (kW), Leaf Wetness, Light Intensity, Power Factor (PF), Pulse Input, Rainfall, Relative Humidity, Soil Moisture, Temperature, Volatile Organic Comp., Volt-Amp Reactive, Volt-Amp Reactive hour, Volt-Amps (VA), Volts (V), Water Flow, Water Level, Watt Hours (Wh), Watts (W) and Wind
*As of 2020, this system may be discontinued due to the following system, being the RX3000, succeeding this system.
For more information visit Onset
- HOBO U30-NRC Station Data Logger
- Mounting kit
- Grounding wire
- Cable entry and sealing kit
- Optional analog sensor port (if ordered)
- Optional sensor expander board (if ordered)
Product Datasheets |
Product Operational Documentation |
Product software |
U30-NRC Datasheet | Replacement Battery for U30 and RX3000 (HRB-U30-S100) Replacement Instructions | HOBOware Pro Growing Degree Days Assistant - User’s Guide |
U30 Remote Monitoring Systems Data Sheet |
HOBO U30 Station (U30-NRC) User's Guide | |
10 Ah rechargeable battery is included in your purchase. The battery will start to run down if it is not recharged. Therefore, the system requires either a solar panel or an AC adapter plugged in to ensure the battery does not run too low. Even rechargeable batteries eventually fail, and will not be able to be recharged. However, you can order replacement batteries when the time arises. HOBO data loggers require HOBOware software and a communications cable (#CABLE-USBMB). HOBOware Pro Mac/Win has the USB cable included in your purchase. (#BHW-PRO-CD)
See the User's Guide for more information.
White Papers |
On-Demand Webinars |
How-To Videos |
Informational Pages |
Application Stories |
Application Solutions |
Live Systems |
Additional Related Content |
Tech Notes |
Self-Guided Training |
||
Finding Hidden Energy Waste with Data Loggers: 8 Cost-Saving Opportunities |
|
||||||||||
Tips for Selecting and Deploying Data Loggers for Building Performance Monitoring |
|
|
|||||||||
|
|
|
|
|
|||||||
Monitoring Wetlands with Data Loggers: A Best Practices Guide |
|
|
|
|
|
Boosting mV outputs to 0-2.5 DC outputs for use with HOBO stand-alone data loggers |
|
||||
The Energy Professional’s Guide to Data Loggers and Building Performance |
|
|
|
|
|
|
|||||
|
|
|
Data Loggers Used in Microclimate Monitoring |
|
|
|
|
||||
|
|
|
Energy Monitoring Program Looks at Low-cost/No-cost Building Efficiency Strategies |
|
|
|
|
||||
|
|
|
Energy Monitoring Program Looks at Low-cost/No-cost Building Efficiency Strategies |
|
|
|
|
||||
|
|
|
|
|
|
|
Enclosure | |
Enclosure Dimensions | 17.8 H x 11.7 D x 19.3 W cm (7.0 H x 4 .6 D x 7.6 W inches) |
Enclosure Material | Outer enclosure: ABS blend with stainless steel hinge pins and bronze inserts Inner enclosure: Polycarbonate with bronze inserts |
External Input | |
External Input Range | User-configurable: 0–20 mA DC, 0-2.5 VDC, 0-5 VDC, 0-10 VDC, or 0–20 VDC |
Logger | |
Alarm Notification Latency | Maximum of 15 (some sensors use more than one data channel) |
Enclosure Access | Hinged door secured by two latches with eyelets for securing with user-supplied padlocks |
External Power | External power is required. The system optionally accepts the following Onset solar panels:SOLAR-1.2W, SOLAR-3W, SOLAR-6W. Alternatively it accepts an AC power adapter:AC-U30 |
Logger Battery Life | Typical 3–5 years depending upon conditions of use. Operation within the extended operating range (but outside the normal range) will reduce battery service life. |
Logger Battery Type | 4 Volt, 4.5 AHr or 10 AHr, Rechargeable sealed lead-acid |
Logger Environmental Rating | Weatherproof enclosure, tested to NEMA 6. (Requires proper installation of cable channel system) |
Logger Memory | Nonvolatile flash data storage, 512K bytes local storage |
Logger Operating Range | -20°C to 40°C (-4°F to 104°F) |
Logger Time Accuracy | 0 to 2 seconds for the first data point and ±5 seconds per week at 25°C (77°F) |
Logger Weight | 2 kg (4 lbs 10 oz) |
Logging Rate | 1 second to 18 hours, user-specified interval |
Memory Modes | Stop when full, wrap around when full |
Operational Indicators | Up to six (depending upon options) status lights provide basic diagnostics |
Sensor Connectors | Compatible with most Onset smart sensors, except for the S-BPA, S-TMA and S-THA |
Materials | |
Cable Entry Bars | Aluminium with ABS plastic thumb screws |
Cable Entry Channel | EPDM rubber |
Gaskets | Silicone rubber |
Inner Enclosure | Polycarbonate with bronze inserts |
Logger Mounting | 3.8 cm (1.5 inches) mast or wall mount |
Logging Interval | 1 second to 18 hours, user-specified interval |
Outer Enclosure | ABS blend with stainless steel hinge pins and bronze inserts |
Sensor Network Cable Length | 3.8 cm (1.5 inches) mast or wall mount |
U-bolts | Steel with zinc dichromate finish |
Optional Analog Sensor Port Specification | |
ADC Resolution | 12 bits |
Analog Sensor Accuracy | ± 0.25% of FSR from 50mV to FSV |
Excitation Power | Switched 12 VDC, up to 50 mA; user-selectable warm-up from 5msec to 2 minutes |
Field Wiring | wo- or three-wire via screw terminals on the detachable connector, 16–24 AWG. |
Input Channels | Two, single-ended |
Input Range | User-configurable: 0–20 mA DC, 0-2.5 VDC, 0-5 VDC, 0-10 VDC, or 0–20 VDC |
Minimum Current Source Impedance | > 20 KΩ |
Minimum/Maximum Input Current | 0 / 24 mA DC |
Minimum/Maximum Input Voltage | 0 / 24 VDC |
Replacement Detachable Connectors | Part of spares kit, Part No. A-FS-CVIA-7P-1 |