Onset

Temp/RH/CO2 Bluetooth Data Logger

Sale priceR 18,063.36
SKU: MX1102A

ACCESSORIES ARE SOLD SEPARATELY.
NOT SURE WHAT TO ORDER? CONTACT US TODAY!

Quantity:
Pickup available at EUCA Head Office Usually ready in 24 hours

Temp/RH/CO2 Bluetooth Data Logger

EUCA Head Office

Pickup available, usually ready in 24 hours

Clearwater Office Park
Parkhaven, Block H Ground Floor
Boksburg
Gauteng
1459
South Africa

+27123623271

Onset’s HOBO MX1102 CO2 logger makes it more convenient than ever to measure and record CO2 in buildings and other non-condensing environments. It measures CO2 from 0 – 5,000 parts per million (ppm) – and our free HOBOconnect app allows you to access data right from your mobile phone or tablet within a 100-feet range.

The MX1102 also features a USB port so it can be used with a computer running HOBOware graphing and analysis software. 

Documentation

Data Sheet
User Manual

 

Highlighted Features

  • Wireless communication via Bluetooth Low Energy (BLE) Technology
  • Six-month battery life at a 5-minute CO2 logging rate
  • Easy to deploy and offload using the free HOBOconnect app
  • Visual and audible high & low alarm thresholds
  • Self-calibrating NDIR CO2 sensor technology ensures optimal accuracy and lower maintenance costs
  • Patented connectivity technology

Specifications

Specification Value
Temperature Sensor
Range 0° to 50°C (32° to 122°F)
Accuracy ±0.21°C from 0° to 50°C (see manual for plot) / ±0.38°F from 32° to 122°F (see manual for plot)
Resolution 0.024°C at 25°C (see manual for plot) / 0.04°F at 77°F (see manual for plot)
Drift <0.1°C per year / 0.18°F per year
RH Sensor
Range 1% to 90% RH (non-condensing)
Accuracy ±2% from 20% to 80% typical (max ±4.5% incl. hysteresis at 25°C/77°F); Below 20% and above 80% ±6% typical
Resolution 0.01%
Drift <1% per year typical
CO2 Sensor
Range 0 to 5,000 ppm
Accuracy ±50 ppm ±5% of reading at 25°C (77°F), less than 90% RH (non-condensing) and 1,013 mbar
Warm-up Time 15 seconds
Calibration Auto or manual to 400 ppm
Non-linearity <1% of FS
Pressure Dependence 0.13% of reading per mm Hg (corrected via user input for elevation/altitude)
Operating Pressure Range 950 to 1,050 mbar (use Altitude Compensation for outside of this range)
Compensated Pressure Range -305 to 5,486 m (-1,000 to 18,000 ft)
Sensing Method Non-dispersive infrared (NDIR) absorption
Response Time (Temperature) 12 minutes to 90% in airflow of 1 m/s / 12 minutes to 90% in airflow of 2.2 mph
Response Time (RH) 1 minute to 90% in airflow of 1 m/s / 1 minute to 90% in airflow of 2.2 mph
Response Time (CO2) 1 minute to 90% in airflow of 1 m/s / 1 minute to 90% in airflow of 2.2 mph
Logger
Radio Power 1 mW / 0 dBm
Transmission Range Approximately 30.5 m line-of-sight / Approximately 100 ft line-of-sight
Wireless Data Standard Bluetooth Low Energy (Bluetooth Smart)
Logger Operating Range 0° to 50°C, 0 to 95% RH (non-condensing) / 32° to 122°F, 0 to 95% RH (non-condensing)
Logging Rate 1 second to 18 hours
Logging Modes Fixed interval (normal, statistics) or burst
Memory Modes Wrap when full or stop when full
Start Modes Immediate, push button, date & time, or next interval
Stop Modes Memory full, push button, date & time, or set logging period
Time Accuracy ±1 minute per month at 25°C/77°F
Power Source 4 AA 1.5 Volt batteries (user replaceable) or USB power source (5 V DC, 2 Watts)
Battery Life 6 months (conditions apply)
Memory 128 KB (84,650 measurements, max)
Download Type USB 2.0 interface or via Bluetooth Smart
Full Memory Download Time 20 seconds via USB; approx. 60 seconds via Bluetooth Smart (depends on device distance from logger)
LCD Visible from 0° to 50°C (32° to 122°F); may react slowly or go blank outside this range
Size 7.62 x 12.95 x 4.78 cm / 3.0 x 5.1 x 1.88 inches
Weight 267.4 g / 9.43 oz
Environmental Rating IP50

Applications 

In what environment does this data logger operate?

This data logger operates in an indoor environment.

What measurements does this data logger support?

The MX1102A data logger supports the following measurements: Carbon Dioxide, Relative Humidity, and Temperature