A weatherproof data logger with two external soil/water temperature probes on 6-foot cables for fast sensor response and deployment in tight spaces.
Documentation
Data SheetUser Manual
Highlighted Features
- Weatherproof housing for use in outdoor or condensing environments
- High accuracy
- Small-diameter external sensor versions for measurements in tight spaces
- Optic USB interface for fast and reliable download
- Compatible with HOBOware and HOBOware Pro software for logger setup, graphing, and analysis
Specifications
Measurement | U23-001A Internal Sensor | U23-002A External Sensor | U23-003 and U23-004 External Sensors |
---|---|---|---|
Operation Range | -40 to 70°C (-40 to 158°F) | -40 to 70°C (-40 to 158°F) | -40 to 100°C (-40 to 212°F), with tip and cable immersion in fresh water up to 50°C (122°F) for one year |
Accuracy | ±0.25°C from -40 to 0°C | ±0.25°C from -40 to 0°C | ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F); see Plot A |
±0.2°C from 0 to 70°C | ±0.2°C from 0 to 70°C | ||
Resolution | 0.04°C (0.072°F) | 0.04°C (0.072°F) | 0.02°C at 25°C (0.04°F at 77°F); see Plot A |
Response Time | 10 minutes in air moving 1 m/sec | 3 minutes, 45 seconds in air moving 1 m/sec | 3 minutes in air moving 1 m/sec; 30 seconds in stirred water |
Drift | <0.01°C (0.018°F) per year | <0.01°C (0.018°F) per year | <0.1°C (0.18°F) per year |
Relative Humidity Sensor | U23-001A, U23-002A only |
---|---|
Operation Range | 0 to 100% RH, -40° to 70°C (-40° to 158°F) |
Exposure to conditions below -20°C (-4°F) or above 95% RH may temporarily increase the maximum RH sensor error by an additional 1% | |
Accuracy | ±2.5% from 10% to 90% RH typical to a maximum of ±3.5% including hysteresis at 25°C (77°F); below 10% and above 90% ±5% typical |
Resolution | 0.05% |
Response Time | 40 minutes in air moving 1 m/sec with protective cap |
15 seconds in air moving 1 m/sec | |
Drift | <1% per year typical |
Logger | |
---|---|
Operation Range | -40° to 70°C (-40° to 158°F) |
Real-time Clock | ±1 minute per month 0° to 50°C (32° to 122°F) |
Battery | 1/2 AA, 3.6 Volt lithium, user-replaceable (HP-B) |
Battery Life (Typical Use) | 3 years with 1 minute or greater logging interval |
Memory (Non-Volatile) | 64K bytes memory (approx. 21,000 temperature and RH measurements) |
Environmental Rating | Electronics housing is NEMA 6P equivalent (tolerant of brief submergence); Units with RH sensors are NEMA 4 equivalent (splash-resistant) |
Launch Modes | Immediate start; delayed start |
Logging Interval | Fixed-rate or multiple logging intervals, with up to 8 user-defined logging intervals and durations; logging intervals from 1 second to 18 hours |
Offload Modes | Offload while logging; stop and offload |
Battery Indication | Battery voltage can be viewed in status screen and optionally logged in datafile. Low battery indication in datafile. |
Weight | U23-001A: 57 g (1.5 oz); U23-002A: 118 g (3.1 oz); U23-003: 138 g (3.7 oz); U23-004: 102 g (2.7 oz) |
Dimensions | Housing measures 10.2 × 3.8 cm (4.0 × 1.5 in.) |
NIST Certificate | Temperature certificate available for additional charge |