Split Core Current Transformers KCT Type
KCT-24 | 200A/333m V
EUCA Head Office
Clearwater Office Park
Parkhaven, Block H Ground Floor
Boksburg
Gauteng
1459
South Africa
This KCT type of split core current transformer is meticulously designed to be compact and easily accessible while maintaining the accuracy required for kWh meters. These transformers offer a significant advantage by allowing seamless placement without disturbing or disconnecting the main cables they monitor.
The KCT transformers feature two insulated terminal covers for connecting S1 and S2 cables, securely locking down over the terminal screws to fully insulate the connections. This design is especially advantageous when used with Autometers cable harnesses, known for their color-coded and individually numbered conductors, ensuring a straightforward and hassle-free connection from the current transformer to the electricity meter.
Highlighted Features
- The structure of the self-locking, is safe, easy to install, portable.
- Wide inner window, allowing clamping of big cables or bus-bars.
- Wide range of sizes to accommodate all the existing installations.
- Isolated plastic case recognized according to UL94-V0.
Applications
- Current measurement, monitoring, and protection for electrical wiring and equipment.
- Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system, air-conditioning equipment, and automation control system.
- Current, power and energy monitoring device.
- Relay protection device
Specifications
KCT-10
Specification | KCT-10 |
---|---|
Current Ratio | 5A/2.5mA, 20A/10mA, 60A/20mA, 75A/25mA, 1~75A/0.333V |
Primary Current | 5A, 20A, 60A, 75A, 1~75A |
Max. Current | 60A, 60A, 750A, 75A, 1~75A |
Output | 2.5mA, 10mA, 20mA, 25mA, 333mV |
Load Resistance | 400Ω, 100Ω, 50Ω, 20Ω, / |
Class | 0.5/1.0 |
Turns Ratio | 2000:1, 2000:1, 3000:1, 3000:1, / |
Protection Level | 7.5V0-P, 7.5V0-P, 7.5V0-P, 7.5V0-P, 7.5V0-P |
Insulation Category | CATIII |
Operating Condition | -20℃~+50℃, ≤85%RH, No condensation, In-house & Any direction installable |
Storage Condition | -30℃~+50℃, ≤85%RH, No condensation |
KCT-16
Specification | KCT-16 |
---|---|
Current Ratio | 100A/33.3mA, 100A/40mA, 120A/40mA, 200A/66.7mA, 100~200A/0.333V |
Primary Current | 100A, 100A, 120A, 200A, 100~200A |
Max. Current | 120A, 120A, 120A, 240A, 240A |
Output | 33.3mA, 40mA, 40mA, 66.7mA, 333mV |
Load Resistance | 50Ω, / |
Class | 0.5/1.0 |
Turns Ratio | 3000:1, 2500:1, 3000:1, 3000:1, / |
Protection Level | 7.5V0-P, 7.5V0-P, 7.5V0-P, 7.5V0-P, 7.5V0-P |
Insulation Category | CATIII |
Operating Condition | -20℃~+50℃, ≤85%RH, No condensation, In-house & Any direction installable |
Storage Condition | -30℃~+50℃, ≤85%RH, No condensation |
KCT-24
Specification | KCT-24 |
---|---|
Current Ratio | 100A/40mA, 200A/40mA, 200A/66.7mA, 400A/80mA, 100~400A/0.333V |
Primary Current | 100A, 200A, 200A, 400A, 100~400A |
Max. Current | 150A, 240A, 240A, 480A, 4800A |
Output | 40mA, 40mA, 66.7mA, 80 |
KCT-36
Specification | KCT-36 |
---|---|
Current Ratio | 300A/50mA, 400A/50mA, 500A/50mA, 600A/50mA, 1600A/0.3333V |
Primary Current | 300A, 400A, 500A, 600A, 1~600A |
Max. Current | 360A, 480A, 600A, 720A, 720A |
Output | 50mA, 50mA, 50mA, 50mA, 333mV~3V |
Load Resistance | 50Ω, 50Ω, 50Ω, 50Ω, / |
Class | 0.5, 0.5, 0.5, 0.5, 0.5 |
Turns Ratio | 6000:1, 8000:1, 10000:1, 12000:1, / |
Protection Level | 7.5V0-P, 7.5V0-P, 7.5V0-P, 7.5V0-P, 7.5V0-P |
Insulation Category | CATIII |
Operating Condition | -20℃~+50℃, ≤85%RH, No condensation, In-house & Any direction installable |